An audiogram is a graph that records the results of a hearing examination by showing the quietest sounds a person can detect at different frequencies. It provides an objective picture of hearing sensitivity in each ear and helps an audiologist identify patterns that may require monitoring, rehabilitation or further assessment.
After an audiometry test Singapore patients may see symbols, numbers and lines that are unfamiliar at first. The horizontal axis represents sound frequency or pitch, while the vertical axis represents hearing level in decibels, commonly written as dB HL.
An audiogram should not be interpreted by looking at one number alone. The overall pattern, differences between the ears, air- and bone-conduction findings and other audiological results need to be considered together.
This guide focuses specifically on understanding audiogram results, including what the axes and symbols represent, how hearing thresholds are plotted and what common hearing patterns can mean.
What Is an Audiogram?
An audiogram is a standard chart used to record hearing thresholds measured during pure tone audiometry. A hearing threshold represents the lowest sound level at which a person reliably responds to a particular frequency under controlled testing conditions.
Each ear is usually tested separately.
The resulting thresholds are plotted across a range of frequencies so that the audiologist can see which pitches are heard more easily and which require greater sound levels to be detected.
An audiogram therefore provides more information than simply stating whether someone has "good" or "poor" hearing.
What Does an Audiogram Measure?
An audiogram primarily measures hearing sensitivity across different sound frequencies.
During pure tone testing, sounds are presented at different levels. The audiologist systematically adjusts these levels to establish the quietest response that can be obtained reliably at each test frequency.
These thresholds form the main points displayed on the audiogram.
The graph can reveal whether hearing sensitivity is similar across frequencies or whether certain pitches are affected more than others.
Understanding the Frequency Chart
The horizontal axis of an audiogram represents frequency, which is measured in hertz, or Hz. Frequency relates to the pitch of a sound.
Lower frequencies appear towards the left side of the graph and represent lower-pitched sounds. Higher frequencies appear towards the right and represent higher-pitched sounds.
Human speech contains information across a range of frequencies, which is one reason hearing is assessed at several pitches rather than using only one test tone.
Low and High Frequencies
Lower-frequency sounds can include deeper components of speech and environmental sounds, while higher frequencies contain important information for speech clarity.
Some hearing patterns affect higher frequencies more than lower ones.
A person may therefore detect that someone is speaking but have difficulty distinguishing certain parts of speech clearly.
This helps explain why hearing difficulty is not always experienced simply as reduced volume.
Understanding Hearing Thresholds
The vertical axis of an audiogram represents hearing level, expressed in dB HL.
Unlike many graphs, softer hearing levels appear towards the top and progressively higher sound levels appear further down.
A threshold plotted lower on the chart therefore means that a stronger sound was required before it could be detected.
This arrangement can initially seem counterintuitive, but it becomes easier to understand once the audiogram is viewed as a record of how much sound was needed to produce a response.
Why Thresholds Matter
Hearing thresholds provide an objective measurement of auditory sensitivity.
For example, if a person requires a higher sound level to detect certain frequencies, those thresholds will appear further down the audiogram.
The audiologist considers the overall pattern rather than focusing on a single threshold.
Small variations can occur between frequencies and between assessments, so professional interpretation is important when determining whether a difference is clinically meaningful.
Understanding the Symbols on an Audiogram
Audiograms use standard symbols to distinguish between ears and testing methods. The exact notation should be explained by the audiologist because the symbols can vary according to how the assessment was conducted.
Air-conduction results for the right and left ears are normally represented separately.
Bone-conduction thresholds use different symbols so they can be compared with air-conduction findings.
This distinction is important because the relationship between these results helps the audiologist characterise the hearing pattern.
Why Each Ear Is Tested Separately
Testing each ear separately allows differences between the ears to be identified.
Someone may feel that their overall hearing is adequate because the better-hearing ear compensates during everyday communication.
Separate testing can reveal asymmetry that may not be obvious when both ears are listening together.
The significance of a difference depends on its size, pattern and associated symptoms.
Air-Conduction Results
Air-conduction testing evaluates hearing through the usual auditory pathway. Sound travels through the outer ear, middle ear and inner ear before auditory information is transmitted towards the brain.
Headphones or insert earphones are commonly used for this part of the hearing examination.
The plotted thresholds show the lowest sound levels detected through this pathway at each tested frequency.
Air-conduction results provide important information about overall hearing sensitivity but do not always show where a hearing difficulty originates.
Bone-Conduction Results
Bone-conduction testing sends vibration through the skull to stimulate the inner ear while reducing the influence of the outer and middle ear.
A small bone vibrator is positioned against the head, commonly behind the ear.
Comparing these thresholds with air-conduction results helps the audiologist determine whether the outer or middle ear may be contributing to the hearing pattern.
Bone-conduction testing is therefore particularly useful when a more detailed classification of hearing loss is required.
Understanding the Air-Bone Gap
An air-bone gap is a difference between air- and bone-conduction thresholds at the same or nearby frequencies that meet relevant clinical criteria.
Its presence can suggest that sound transmission through the outer or middle ear is contributing to reduced hearing sensitivity.
The size and pattern of the gap need professional interpretation.
An air-bone gap should not be used by a patient to self-diagnose a specific ear condition because several factors need to be considered alongside the audiogram.
Common Types of Hearing Loss on an Audiogram
Audiologists commonly classify hearing patterns as conductive, sensorineural or mixed based on the relationship between air- and bone-conduction results.
These classifications describe the general hearing pathway involved. They do not necessarily identify the exact medical cause.
| Hearing Pattern | General Audiogram Finding | Main Area Involved |
|---|---|---|
| Conductive | Air conduction poorer than bone conduction with a relevant gap | Outer or middle-ear sound transmission |
| Sensorineural | Air and bone thresholds are both reduced without a significant conductive gap | Inner ear or auditory pathway |
| Mixed | Reduced bone thresholds with an additional conductive component | Combination of mechanisms |
Further assessment may be required to understand the underlying reason for a particular pattern.
Conductive Hearing Loss
A conductive hearing pattern occurs when sound transmission through the outer or middle ear is reduced while inner-ear sensitivity is relatively better.
On an audiogram, this may appear as poorer air-conduction thresholds compared with bone-conduction thresholds.
Several conditions can produce conductive patterns, so the audiogram alone does not determine the medical cause.
Additional assessment of the ear and middle-ear system may be appropriate depending on the findings.
Sensorineural Hearing Loss
A sensorineural hearing pattern occurs when hearing changes involve the inner ear or auditory pathways beyond the middle ear.
Air- and bone-conduction thresholds are generally reduced to a similar degree without a clinically significant air-bone gap.
The shape and severity can vary considerably between people.
Some sensorineural patterns affect high frequencies more than low frequencies, while others have different configurations.
The audiologist interprets the pattern together with hearing history, symptoms and additional testing where required.
Mixed Hearing Loss
Mixed hearing loss contains both conductive and sensorineural components.
The bone-conduction results indicate reduced inner-ear hearing sensitivity, while the air-conduction results show an additional reduction related to sound transmission through the outer or middle ear.
Because more than one mechanism is involved, the next steps depend on the complete clinical picture.
Audiological and medical evaluation may both be relevant.
Understanding Hearing Loss Levels
Audiologists may use descriptive categories to communicate the degree of hearing loss based on hearing thresholds.
Terms such as mild, moderate, severe or profound can provide a general description, but they should not be interpreted as a complete measure of how someone functions in everyday communication.
Two people with similar pure tone thresholds can experience different listening difficulties.
Speech understanding, listening environment, communication demands and other factors influence real-world hearing.
The audiogram is therefore an important measurement, but it is only one part of a broader hearing evaluation.
Why the Shape of an Audiogram Matters
The configuration of an audiogram describes how thresholds change across frequencies.
Some audiograms remain relatively similar across the tested frequency range, while others slope, rise or show more localised changes.
A sloping pattern, for example, may indicate that higher frequencies require stronger sound levels than lower frequencies.
The shape can help explain why certain sounds are easier to hear than others.
However, similar-looking configurations can arise for different reasons, so audiogram shape should not be treated as a diagnosis by itself.
What Does an Audiogram Say About Speech Understanding?
An audiogram shows hearing sensitivity to pure tones, but everyday communication involves complex speech rather than isolated tones.
Pure tone results can help explain why certain parts of speech may be difficult to detect.
However, they do not completely predict how well someone will understand conversation, particularly in background noise.
Speech audiometry may therefore be included in a hearing evaluation to provide additional information about speech detection or recognition.
This is one reason two people with apparently similar audiograms may report different levels of communication difficulty.
Why Background Noise Can Still Be Difficult
Difficulty understanding speech in background noise is a common hearing complaint and cannot always be predicted from a simple glance at the audiogram.
Busy environments require the auditory system to separate speech from competing sounds while the brain processes rapidly changing information.
Pure tone audiometry measures sound detection under controlled conditions rather than recreating every real-world listening environment.
Your description of where hearing becomes difficult therefore remains important even when reviewing objective results.
What If One Ear Is Different From the Other?
Differences between the ears are called asymmetry.
Small variations can occur, but a more substantial or unusual difference may influence what the audiologist recommends next.
The interpretation depends on which frequencies are affected, the size of the difference and whether symptoms such as tinnitus or other ear concerns are present.
An audiologist can determine whether the pattern requires monitoring, additional testing or medical evaluation.
Patients should avoid trying to determine the significance of asymmetry from a single threshold without considering the complete assessment.
Can an Audiogram Identify the Cause of Hearing Loss?
An audiogram can help classify the hearing pattern, but it cannot always establish the precise cause.
For example, air- and bone-conduction findings may suggest that a conductive component is present, but additional examination may be needed to determine why.
Similarly, a sensorineural pattern identifies the general mechanism of hearing change without necessarily revealing the underlying medical explanation.
Hearing history, ear examination, middle-ear testing and medical evaluation may all contribute additional information.
What Happens After Your Audiogram Is Reviewed?
The next step depends on the hearing examination results, symptoms and communication needs.
Some people may have hearing thresholds that do not require immediate intervention. Others may need monitoring, additional audiological assessment, hearing rehabilitation or medical review.
If hearing aids are being considered, the audiogram can contribute important information for the hearing aid evaluation and fitting process.
The appropriate recommendation should reflect the individual rather than the audiogram alone.
Questions to Ask About Your Results
Understanding your results is more useful than simply receiving a copy of the graph.
Useful questions include:
- What does the overall pattern of my audiogram show?
- Are both ears similar?
- Which frequencies show the greatest hearing change?
- Do the findings help explain my everyday communication difficulties?
- Is monitoring or further assessment recommended?
These questions focus the discussion on how the measurements relate to practical hearing needs.
Frequently Asked Questions (FAQs)
An audiogram is a graph that displays hearing thresholds across different frequencies for each ear. It is commonly produced during pure tone audiometry and forms an important part of a diagnostic hearing examination.
Softer hearing levels are shown near the top of the graph and higher sound levels appear further down. A threshold located lower on the audiogram therefore means that a stronger sound was required before it could be detected.
Frequency describes the pitch of a sound and is measured in hertz. Lower frequencies correspond to lower-pitched sounds, while higher frequencies represent higher-pitched sounds. Testing several frequencies shows whether hearing sensitivity changes across different pitches.
A hearing threshold is the lowest sound level at which a person responds reliably to a particular test frequency. These thresholds are plotted on the audiogram for each ear.
An air-bone gap is a clinically relevant difference between air- and bone-conduction thresholds. It may indicate that an outer- or middle-ear component is affecting sound transmission. The finding requires interpretation alongside the rest of the hearing assessment.
Yes. Pure tone audiometry measures sound detection under controlled conditions and does not represent every aspect of everyday communication. Difficulties with speech in noise or complex listening environments should still be discussed with an audiologist.
An audiogram provides important information for hearing aid evaluation, but it does not make the decision by itself. Communication difficulties, hearing needs, speech findings and individual circumstances also need to be considered.
Yes, previous results can be useful for comparison during future assessments. They may help an audiologist determine whether hearing thresholds have remained stable or changed over time.
Turning the Audiogram Into Useful Hearing Information
An audiogram is more than a collection of symbols and lines. It shows how softly different frequencies can be detected in each ear and provides important information about the pattern of hearing sensitivity.
Frequency appears across the horizontal axis, while hearing level appears vertically. Air- and bone-conduction results allow the audiologist to distinguish between conductive, sensorineural and mixed hearing patterns where appropriate.
The graph does not tell the entire story of a person's hearing. Speech understanding, listening environments, symptoms and communication needs also influence how hearing difficulties are experienced.
The most useful interpretation therefore comes from connecting the audiogram with the complete hearing examination rather than trying to interpret individual numbers in isolation.
Understand Your Hearing Results with Ear Balance
If you have completed a hearing test or want a clearer understanding of your current hearing function, Ear Balance provides hearing assessment and diagnostic services in Singapore. You can book a consultation to have your hearing evaluated and discuss what the results may mean for your communication needs.